Experimental investigation into the potential of using a shallow ground-cooled condenser in Lebanon

dc.contributor.authorAlkhedher, Mohammad
dc.contributor.authorMahmoud, Montaser
dc.contributor.authorOlabi, Abdul-Ghani
dc.contributor.authorETAL..
dc.date.accessioned2024-06-05T10:19:40Z
dc.date.available2024-06-05T10:19:40Z
dc.date.issued2022-06-15
dc.descriptionRenewable energy sources (RES) are considered to be the leading contenders for developments of energy systems that reduce or eliminate the use of fossil fuels and thereby decreasing their environmental impacts [1]. However, RES are usually characterized by their stochastic and intermittent natures such as solar [2] and wind [3] energies. This imposes a need to incorporate energy storage systems in order to mitigate fluctuations and provide continuous supply [4], [5]. Such systems may also have some impacts on the environment and so making RES-based systems not perfectly green. For these reasons, geothermal energy (GE) can be considered as one of the most attractive energy sources [6], [7].
dc.description.abstractThe aim of this paper is to investigate the potential of using shallow geothermal energy in Lebanon for cooling a power cycle. The study includes ground temperature measurement, operating system management, and pressure drop assessment. Temperatures were monitored at six positions underground reaching to a depth of 2 m in Bekaa-Lebanon during the whole of 2020. The temperature sensors were placed at depths of 0.3, 0.6, 1, 1.3, 1.6, and 2 m underground. At 2 m depth, the ground temperature showed high stability with an annual temperature difference of 7 °C, while that of high and low ambient temperatures were 40 °C and 33 °C, respectively. Based on the comparison between ambient and ground temperatures, the ground cooling system can operate 207 days/year partially with full operations of 51 days. This shows that shallow geothermal energy has a great potential to activate a ground-based cooling system in this region. However, to avoid heat accumulation, use of another heat exchanger is recommended to support the ground cooling system. This heat exchanger can also provide coolth compensation when the power cycle is turned off. The pressure drop inside the heat exchangers was found to be highly significant, hence, it was essential to add an intermediate water loop between the power cycle and the ground loop. Keywords: Shallow geothermal energy, Ground temperature, Ground heat exchanger, Ground-cooled condenser, Power generation
dc.identifier.citationMahmoud, M., Alkhedher, M., Ramadan, M., Pullen, K., Olabi, A. G., & Naher, S. (2022). Experimental investigation into the potential of using a shallow ground-cooled condenser in Lebanon. Energy Conversion and Management, 264, 115729.
dc.identifier.doihttps://doi.org/10.1016/j.enconman.2022.115729
dc.identifier.urihttps://dspace.adu.ac.ae/handle/1/5685
dc.language.isoen
dc.publisherElsevier
dc.titleExperimental investigation into the potential of using a shallow ground-cooled condenser in Lebanon
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Experimental investigation.pdf
Size:
3.38 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: