The Role of 3D CT Imaging in the Accurate Diagnosis of Lung Function in Coronavirus Patients

dc.contributor.authorFarahat, Ibrahim Shawky
dc.contributor.authorSharafeldeen, Ahmed
dc.contributor.authorElsharkawy, Mohamed
dc.contributor.authorETAL.
dc.date.accessioned2023-04-27T05:54:13Z
dc.date.accessioned2023-08-20T11:14:34Z
dc.date.available2023-04-27T05:54:13Z
dc.date.available2023-08-20T11:14:34Z
dc.date.issued2022-03
dc.description.abstractEarly grading of coronavirus disease 2019 (COVID-19), as well as ventilator support machines, are prime ways to help the world fight this virus and reduce the mortality rate. To reduce the burden on physicians, we developed an automatic Computer-Aided Diagnostic (CAD) system to grade COVID-19 from Computed Tomography (CT) images. This system segments the lung region from chest CT scans using an unsupervised approach based on an appearance model, followed by 3D rotation invariant Markov–Gibbs Random Field (MGRF)-based morphological constraints. This system analyzes the segmented lung and generates precise, analytical imaging markers by estimating the MGRF-based analytical potentials. Three Gibbs energy markers were extracted from each CT scan by tuning the MGRF parameters on each lesion separately. The latter were healthy/mild, moderate, and severe lesions. To represent these markers more reliably, a Cumulative Distribution Function (CDF) was generated, then statistical markers were extracted from it, namely, 10th through 90th CDF percentiles with 10% increments. Subsequently, the three extracted markers were combined together and fed into a backpropagation neural network to make the diagnosis. The developed system was assessed on 76 COVID-19-infected patients using two metrics, namely, accuracy and Kappa. In this paper, the proposed system was trained and tested by three approaches. In the first approach, the MGRF model was trained and tested on the lungs. This approach achieved 95.83% accuracy and 93.39% kappa. In the second approach, we trained the MGRF model on the lesions and tested it on the lungs. This approach achieved 91.67% accuracy and 86.67% kappa. Finally, we trained and tested the MGRF model on lesions. It achieved 100% accuracy and 100% kappa. The results reported in this paper show the ability of the developed system to accurately grade COVID-19 lesions compared to other machine learning classifiers, such as k-Nearest Neighbor (KNN), decision tree, naïve Bayes, and random forest. © 2022 by the authors. Licensee MDPI, Basel, Switzerland.
dc.identifier.citationFarahat, I. S., Sharafeldeen, A., Elsharkawy, M., Soliman, A., Mahmoud, A., Ghazal, M., ... & El-Baz, A. (2022). The role of 3D CT imaging in the accurate diagnosis of lung function in coronavirus patients. Diagnostics, 12(3), 696.
dc.identifier.doihttps://doi.org/10.3390/diagnostics12030696
dc.identifier.urihttps://edms.wexl.in/handle/1/4559
dc.subjectComputer assisted diagnosis (CAD)
dc.subjectCOVID-19
dc.subjectMachine learning
dc.subjectMarkov–Gibbs Random Field (MGRF)
dc.subjectNeural network
dc.titleThe Role of 3D CT Imaging in the Accurate Diagnosis of Lung Function in Coronavirus Patientsen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
diagnostics-12-00696-v2.pdf
Size:
10.74 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description:

Collections