Analysis and optimization of a modified Kalina cycle system for low-grade heat utilization
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Kalina cycle system (KCS) offers an attractive prospect to produce power by utilizing low-grade heat sources
where traditional power cycles cannot be implemented. Intending to explore the potential of exploiting lowgrade heat sources for conversion to electrical energy, this study proposes two modified power generation cycles based on KCS-34. A multi-phase expander is positioned between the Kalina separator and the second heat
regenerator in the proposed X-modification. In contrast, it is located between the mixer and second regenerator
for Y-modification. To explore the potential benefits and limitations of the proposed modifications contrasted
with the KCS-34, thermodynamic modeling and optimization have been conducted. The influence of critical
decision parameters on overall cycle performance is analyzed. The result elucidates that by implementing an
additional multi-phase expander, a significant amount of energy can be extracted from a lean ammonia water
loop and X-modification can deliver superior thermodynamic performance compared with the Y-modification
and the original KCS-34. With a reduced turbine inlet pressure of 58 bar and an ammonia concentration of 80%,
the X-modified cycle’s efficiency reaches a peak value of 17% and a net power yield of 1015 kW. An increase of
6.35% can be achieved compared with the conventional KCS-34 operating at the same conditions. Maximum
exergy destruction of the working substance was observed in the condenser.
Citation